q The 3rd
Generation GC |
|
q Fast
Column Oven |
|
q Various
Inlets and Detectors |
|
q
Fully Automated Operation |
|
q
Advanced Pneumatic Control |
|
q Economical
Price |
|
|
|
|
Oven Stability : < 0.1 °C |
|
Max Temperature : upto 450 °C |
|
Temperature programmable rate : upto 100 °C/min |
|
Oven ramps/plateaus : 15/16 |
|
Rate stability
: < 0.53 °C |
|
RSD
= 0.20 °C at Rate 20 °C/min |
|
Cool-down rate : 6.5 min from 450 °C to 50 °C |
|
Cryogenic Cooling : down to – 80 °C with N2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Split/splitess, Packed and On-column |
|
-
Upto 2 inlets installed |
|
- APC
available for Split/splitess and Packed |
|
-
Temperature upto 450 °C |
|
- Temperature
stability : ± 0.3 °C |
|
6 or 10-port Gas Sampling Valve |
|
-
Upto 4 Valves installed |
|
-
Upto 30 event controls for GSVs |
|
|
|
|
FID, TCD, NPD, FPD, PD-ECD, PD-HID and ECD |
|
- Up
to 2 detectors installed |
|
- APC
available for FID, TCD, NPD and PDD |
|
-
Temperature up to 400 ~ 450 °C |
|
- Temperature
stability : ± 0.3 °C |
|
|
|
|
|
|
|
|
|
|
Acme Autosampler |
|
-
Unattended operation upto 110 samples |
|
-
Control by GC or Autochro-2000 |
|
(available on the end of 2001) |
|
-
Sampling and injection : 0.1 ~ 100 ul |
|
- Dual
port injection |
|
-
Internal standard sampling |
|
-
Variable fill speed for wide range of sample viscosities |
|
-
Programmable sampling & injection speed |
|
|
|
|
Full Keyboard Control |
|
- 4X20
matrix VFD |
|
- Tree
based menu by each function |
|
- Ramps
key : initial, rate, final, ready, run |
|
- Run
Key : START STOP ▼,▲ ,
PLUS |
|
- Setup
Key : Oven, Inlet1, Inlet2, Det1, Det2 |
|
Signal1,2, SETUP, Special |
|
-
Sequence Key : Method, Sequence, Run Control |
|
Ready RUN, post run |
|
- Etc :
Time, Display, Delete |
|
|
|
|
Autochro-2000 Data System |
|
- Based
on MS Windows XP |
|
- Data
acquisition and processing for |
|
Acme
6000 GC |
|
-
Control of Acme 6000 and |
|
Acme
6000 Autosampler |
|
(available on the 2H of 2002) |
|
-
Automatic TXT format data creation |
|
|
|
|
q Upto 12 CHs for inlets, detectors and
auxiliary gases |
|
q Pressure setting range : 1 ~ 100 psi at
0.1 psi setting |
|
q Split/splitless inlet |
|
: 0-200ml/min N2, 0-1000ml/min H2 or He |
|
q Packed inlet : 0 - 100ml/min |
|
q Fully controlled by Keyboard and/or
Autochro-2000 |
|
Data System(on the 2H of 2002) |
|
q Constant Flow and Pressure |
|
q Ramped Flow and Pressure |
|
q Gas saving & FID Auto-ignition |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|