Acme 6000 GC
The 3rd Generation
Acme 6000 GC
Acme 6000 GC
Acme 6000 GC
Acme 6000 GC
Acme 6000 GC
Features
q   The 3rd Generation GC
q   Fast Column Oven
q   Various Inlets and Detectors
q   Fully Automated Operation
q   Advanced Pneumatic Control
q   Economical Price
Fast Column Oven
Oven Stability : < 0.1 °C
Max Temperature : upto 450 °C
Temperature programmable rate : upto 100 °C/min
Oven ramps/plateaus : 15/16
Rate stability  : < 0.53 °C
                       RSD  = 0.20 °C  at Rate 20 °C/min
Cool-down rate : 6.5 min from 450 °C to 50 °C
Cryogenic Cooling : down to – 80 °C with N2
Oven Temperature Stability(1)
Oven Temperature Stability(2)
Oven Temperature Stability(3)
Oven-In-Side Temperature Deviation
Oven Temp Ramping Stability(1)
Oven Temp Ramping Stability(2)
Oven Temp Ramping Stability(3)
Inlets available
Split/splitess, Packed and On-column
    - Upto 2 inlets installed
    - APC available for Split/splitess and Packed
    - Temperature upto 450 °C
    - Temperature stability : ± 0.3 °C
6 or 10-port Gas Sampling Valve
    - Upto 4 Valves installed
    - Upto 30 event controls for GSVs
Detectors available
FID, TCD, NPD, FPD, PD-ECD, PD-HID and ECD
    - Up to 2 detectors installed
    - APC available for FID, TCD, NPD and PDD
    - Temperature up to 400 ~ 450 °C
    - Temperature stability : ± 0.3 °C
Inlets & Detectors
Temperature Stability
Inlets temperature Stability
Detectors temperature Stability
Fully automated operation
Acme Autosampler
  - Unattended operation upto 110 samples
  - Control by GC or Autochro-2000
    (available on the end of 2001)
  - Sampling and injection : 0.1 ~ 100 ul
 - Dual port injection
  - Internal standard sampling
  - Variable fill speed for wide range of sample viscosities
  - Programmable sampling & injection speed
Fully automated operation(Cont.)
Full Keyboard Control
  - 4X20 matrix VFD
  - Tree based menu by each function
  - Ramps key : initial, rate, final, ready, run
  - Run Key : START STOP  ▼,▲ , PLUS
  - Setup Key : Oven, Inlet1, Inlet2, Det1, Det2
         Signal1,2, SETUP, Special
  - Sequence Key : Method, Sequence, Run Control
         Ready RUN, post run
  - Etc : Time, Display, Delete
Fully automated operation(Cont.)
Autochro-2000 Data System
  - Based on MS Windows XP
  - Data acquisition and processing for
    Acme 6000 GC
  - Control of Acme 6000 and
    Acme 6000 Autosampler
    (available on the 2H of 2002)
  - Automatic TXT format data creation
Advanced
Pneumatic Control
q   Upto 12 CHs for inlets, detectors and auxiliary gases
q   Pressure setting range : 1 ~ 100 psi at 0.1 psi setting
q   Split/splitless inlet
         : 0-200ml/min N2, 0-1000ml/min H2 or He
q   Packed inlet : 0 - 100ml/min
q   Fully controlled by Keyboard and/or Autochro-2000
      Data System(on the 2H of 2002)
q   Constant Flow and Pressure
q   Ramped Flow and Pressure
q   Gas saving & FID Auto-ignition
Slide 26
Advanced Pneumatic Control(cont.)
Advanced Pneumatic Control(cont.)
Advanced Pneumatic Control(cont.)
Slide 30