autosampler autosamplers headspace liquid gc hta ht300 ht200h ht250d ht400e
HT400H HT250D HT300
     
         
 
spacer


Autosamplers from NLG

NLG Analytical offer the full range of HTA Autosamplers for GC, HPLC and Automated SPE applications. Hta has created a workstation that can execute all the operations for liquid handling and sample preparation in an automatic and efficient manner. It is very accurate, precise and fast. It is also elegant, good looking, innovative, flexible and low cost.

For fast and flexible HPLC Autosamplers visit http://www.nlg-analytical.co.uk/hplcandgc.php

Request a catalogue

View Online

HT200H Headspace Autosampler
HT250D Liquid GC & Headspace Duet Autosampler
HT300A Liquid GC Autosampler
HT400E Automated SPE
Autosampler Homepage

 

spacer  


HT300A/HT310A Liquid GC Autosamplers

HT300A Liquid GC AutosamplerWorks with your current GC!

The HT300A is a GC autosampler made to meet the liquid injection needs of your Gas Chromatography analysis. A simple, elegant, reliable and inexpensive way to extend the life of your existing GC!

The HT300A provides a direct replacement for an HP5890 autosampler and is also compatible with GCs from Agilent, Shimadzu, Varian, Perkin-Elmer, Carlo Erba and many more.

» Watch a video of the HT300A in use

The autosampler is available with a 10 position fixed (HT310A) tray or with a 110 position rotating tray (HT300A) for 2 or 2.5ml vials. Syringes of 1 to 100µl may be used and with the option of a special large injection version, this can be increased to 1000µl per sample.

HT300A Mounted on Shimadzu GC
HT300A Injecting into Shimadzu GC

The HT300A is easily installed on all major GCs. The tray can be mounted on either side.

Key features:

• Syringe may be washed with solvent or sample
• Injections may be made on two columns (high throughput and confirmation mode)
• Rotating head design leaves injection port free for manual injection
• Internal standard sampling
• Memory stores 10 different methods
• Variable fill speed allows for wide range of sample viscosities
• Sampling system eliminates air bubbles
• Programmable sampling and injection speed

Easy setup and operation:
The instrument can be controlled by the user-friendly integrated keypad, or by a PC using the HT-COMSoft Software.

The automatic injection sequence may have up to 15 steps that can be programmed to include:
• First sample of group
• Last sample of group
• Analytical method
• Number of injections for each sample
• Pre- and Post-washing solvent position
• Internal Standard position (if used).

HP5890 autosampler replacement:

HTA have developed a software interface that allows the HT300A to be controlled via the popular Agilent Chemstation® providing many benefits including:

• No requirement to replace a functional GC
• Direct replacement gives identical results using the same methods
• No re-training required — minimum expense and downtime
• Full compatibility with all other major models of GC for easy migration at a later date

Using the interface is easy. A pop-up window allows the autosampler to be programmed using the required injection method whilst the GC method is programmed in the normal way.

The interface allows the full injection parameters of the HT300A to be used, such as internal standards, even though these options may not have been available with some of the Agilent auto-injectors.

The HT300A is not only compatible with the HP5890 and HP6890 GCs, but with all other major models of GC in use today. If you upgrade an old autosampler to the HT300A and the GC is changed later on, the sampler has the ability to migrate to any new GC type and is therefore a very cost-effective option.

Internal standards:

Internal standards are used to ensure your analyses are accurate and to make allowances for any variations in the GC performance. The internal standard should have a predictable retention time (that is completely resolved from the rest of the sample) and should make up a known amount of the total sample injected.

Using internal standards on the HT300A is simple and does not require any samples to be measured or weighed. The volumes of the internal standard and the sample are entered into the method. The sampler first pulls up the internal standard, then inserts an air gap to prevent mixing, followed by the main sample. In this way it is easy to ensure that a defined proportion of the injected sample is made up using the internal standard.e

The HT310A for small sample numbers

The 10 sample HT310A autosampler provides an economical solution if you need the high level of reproducibility that an autosampler gives, but do not run large sample batches.

The HT310A has a fixed ‘Pocket’ that holds up to 10 sample vials and gives the autosampler a very small footprint. It uses a similar interface to the HT300A and can be interfaced with most gas chromatographs. The functionality and ease of use remains the same as the 110 position HT300A and software control is available if required. Up to 10 sample methods can be stored and the autosampler includes control over all injection parameters.

Specifications
Syringe Sizes: 1, 10, 25, 50, 100 & 1000µl
(1000µl with large volume version only)
GC Compatibility:
Agilent/HP 4890
Agilent/HP 5890
Agilent/HP 6850A
Agilent/HP 6890
Carlo Erba 5300 Mega
Carlo Erba 8000
Carlo Erba 8000 Top
Carlo Erba 8500 Mega 2
Chemito 1000
Chrompack CP9001/2
Dani 8610/8500
Donam DS6200
Gow Mac*
Kristallux 4000M
Meta Chrom*
Perkin Elmer XL
Shimadzu GC-14A/B/C
Shimadzu GC-17A
Shimadzu GC-2010
Shimadzu GC-2014
Shimadzu QP-2010
SRI 8610*
Trace SX
Varian 3300/3400
Varian 3800
Varian 3900
Younglin*

* Only if specified when ordering the GC

If your GC is not listed it may still be compatible. Please contact us for details.
Tray Capacity
Sampling: 110 vials (HT300A) or 10 vials (HT310A), 2 or 2.5ml
Sample Volume: Steps of 0.1µl
Air Volume: Steps of 0.1µl
Aspirating Speed: 1 - 100µl/sec
Needle Washing: Up to 15 strokes
Washing Mode: Every injection, sample or step
Air Bubble Removing: Up to 15 strokes
Viscosity Time: 1 - 15secs
Injection
Injection Speed: 0.1 - 100µl/sec
Waiting Time
(before and after inject):
0 - 99secs
Injection Depth: Variable
Internal Standard Technique
IS Volume: Steps of 0.1µl
Air Gap Volume: Steps of 0.1µl
Mode: 1 or 2 air gaps
Control
Electrical Control: RS232 and TTL
Physical Characteristics
Dimensions (W x H x D): 420 x 520 x 400mm (HT300A)
270 x 520 x 400mm (HT310A)
Mass: 9.0kg (HT300A)
8.0kg (HT310A)

Datasheet

Adobe PDFHT300A Datasheet (933KB)


 

nlg analytical ltd - enhance laboratory efficiency

NLG Analytical Contact: NLG Analytical Ltd, 16 John Bradshaw Court, Alexandria Way, Congleton Business Park, Congleton, Cheshire, CW12 1LB, UK
Tel: +44(0)1260 274-266 Fax: +44(0)1260 273-319 e-mail: info@nlg-analytical.co.uk

Service | HPLC & GC | v-kit | Data systems | Vials & filters | Jobs @ NLG | About us | Contact us | News | Site map | Newsletter sign-up | Home

© nlg analytical ltd 2008 :: website by thinlinecreative