NLG Analytical
Skip to content
Products and Services

Onsite HPLC Training Course - Level 2

General Maintenance and troubleshooting
 

1 day – 3 people
 
This course is one of our standard company programmes and can be delivered to your people at a venue and date of your choice.
 
If it is not exactly what you want then we can either create a tailored course based on our extensive engineering background and expertise or produce a fully bespoke training course for you.
 
Course Overview:
The purpose of this course is to demonstrate basic user level maintenance and care of the instrument  i.e. ‘Good Use Practice’. Furthermore users will walk through common issues, symptoms, causes, diagnosis and solution in each case.
 
Trainees will be given a number of hands-on tasks and the opportunity to troubleshoot real examples from fault logs provided to our engineers and observations made in FDA/GLP environments.
On successful completion of the training all candidates will receive training certificates
 

Programme contents

Cause and Remedy of…
  • Peak Fronting
  • Broad Peaks
  • Ghost Peaks
  • Baseline drift
  • Baseline noise
  • High Pressure readings
  • Pressure fluctuations
  • Leaks
  • Peak Tailing
  • Poor resolution
Instructions will involve aspects of checking, replacing, purging, unblocking, resetting, tightening, cleaning, etc…
 
Please reply by email or contact me by phone for more details, or to arrange

:
 
Nick Bayliss,  
Sales Manager – NLG Analytical Ltd
direct: 01260 285 805 mobile: 07961 213 581

 Overview of the Pump 
  • Exchanging the Outlet Ball Valve
  • Exchanging the Purge Valve Frit or the Purge Valve
  • Exchanging the Active Inlet Valve
  • Removing the Pump Head Assembly
  • Exchanging the Pump Seals
  • Exchanging the Plungers
  • Performing pressure test
  • Performing leak test 
Overview of the Autosampler 
  • Sampling Sequence
  • Injection Sequence 
  • Exchanging the Needle Assembly
  • Exchanging the Needle-Seat Assembly 
  • Exchanging the Stator Face, Rotor Seal & Isolation Seal 
  • Exchanging the Metering Seal and Plunger
  • Mainpass and Bypass pressure test
Overview of the Detector 
  • Lamp Ignition Routine 
  • Exchanging the Lamp
  • Performing the Intensity Test 
  • Checking the Photocurrent 
  • Cleaning/Replacing the Flow Cell
  • Cleaning the achromatic lens
 
 

 
     
     
     
     


    Basket
    British Pound - GBP
    Your basket is empty.

    Add using Quick Order...



    NLG Analytical is operated by NLG Analytical Ltd, 16 John Bradshaw Court, Alexandria Way, Congleton Business Park, Congleton, Cheshire, CW12 1LB, UK

    Tel: +44(0)1260 274-266 Fax: +44(0)1260 273-319

    © 2012 NLG Analytical Ltd. All rights reserved.

    sectionid=601&urltype=7&sssectionid=601&totype=ARTICLE&toid=94&pagetemplateid=5&pagetemplatecode=&articleid=94&language=en&sssectionname=Onsite+HPLC+Training+Course+-+Level+2&brandid=1
    Page as at 23 May 2012 12:44:55.